Technical Papers Plastics
A quicker method for determination of amorphous content of crystalline polymer

A quicker method for determination of amorphous content of crystalline polymer

Techno - commercial information on plastics Industry - News on Plastics Industry - Plastemart.com
 
A quicker method for determination of amorphous content of crystalline polymer
A quicker method for determination of amorphous content of crystalline polymer  
 

A new and quicker chromatographic method for determination of xylene soluble content of crystalline polymers like Polypropylene (PP) has been developed. The proprietary Viscotek Fipa technique is based upon a fast chromatographic means of separating polymers from the low molecular weight matrix of additives, monomers or solvent they may be mixed with, employing triple detector technology. The Fipa technique yields precise and accurate average molecular weight, molecular size, intrinsic viscosity and data on branching or copolymer composition in only a few minutes, without the need for elaborate sample preparation.

In a report, the authors compare the Viscotek Fipa experimental procedures with the traditional gravimetric method used to determine xylene solubles in process polymers. The xylene soluble test is designed to measure the amorphous content of polypropylene and ethylene-propylene rubber materials. The accuracy and precision of the xylene soluble test are very important to the process and product specifications of the resultant materials.

Using an ethylene-propylene rubber polymer, identical samples were analyzed by both the gravimetric and Viscotek Fipa methods. A correlation factor of 0.9998 shows a high degree of agreement between the results obtained by the two methods. The report demonstrates the speed, accuracy, precision and additional molecular weight/intrinsic viscosity information advantages offered by the Viscotek Fipa technology that are driving many polypropylene producers and catalyst research organizations to adopt the new technique as their preferred method.

When compared to the open vessel operation of the gravimetric method, Viscotek says the Fipa technique offers additional health and safety benefits. Even in laboratories with a moderate sample load, the time and labour savings made compared to the traditional method can easily pay for a system in less than one year.
The Fipa system operates up to 80C - allowing screening of most polymers including polycarbonates, polyacrylates, olefins, rubbers, polyamides, polystyrene and polyvinylalcohol.

{{comment.Name}} made a post.
{{comment.DateTimeStampDisplay}}

{{comment.Comments}}

COMMENTS

0

There are no comments to display. Be the first one to comment!

*

Email Id Required.

Email Id Not Valid.

*

Mobile Required.

*

Name Required.

*

Please enter Company Name.

*

Please Select Country.

Email ID and Mobile Number are kept private and will not be shown publicly.
*

Message Required.

Click to Change image  Refresh Captcha
Dispenser Pump, Spray Pump

Dispenser Pump, Spray Pump