Antibacterial, antifouling polymer coatings to help avoid catheter-associated infections in the blood

14-Feb-13
Catheters are made of flexible low-toxicity silicon rubber that is prone to colonization by bacteria or other microbes. Once settled, these microbes form a biofilm that provides resistance to antimicrobial agents and the body's immune response. These biofilms are the leading cause of potentially lethal healthcare-related infections. To prevent this build-up, or fouling, a team led by Yi-Yan Yang from the A*STAR Institute of Bioengineering and Nanotechnology (IBN) has developed a simple and effective method to modify the rubber surface of catheter tubing. As per phy.org, the team altered the silicon rubber using antimicrobial and antifouling copolymers consisting of a polyethylene glycol (PEG) polymer linked to a strand of polycarbonate polymer. The polycarbonate strand was composed of positively charged hydrophilic and hydrophobic units, or monomers. Adopting a cleverly low-effort strategy, the team modified the rubber surface with a reactive substance known as dopamine, and then simply dipped the pre-coated surface in a solution containing the polymer precursors to anchor the copolymer chains. The researchers determined the antibacterial and antifouling performance of the coatings by incubating the multidrug-resistant Staphylococcus aureus Gram-positive bacteria with the treated rubber. All coatings exhibited antifouling properties thanks to their flexible and bulky PEG portions, which prevented microbial cells from approaching the rubber surface. Furthermore, only coatings that contained hydrophobic monomers in the positively charged polycarbonate killed bacteria in solution. This highlights the importance of these monomers, which may insert into bacterial membranes and thereby enhance the interaction between polymer and bacteria. Noting that very few red blood cells ruptured upon contact with the coatings, Yang says that there was no blood protein adsorption or platelet adhesion on the treated surface—proof of the excellent blood compatibility of the polymers.
  More News  Post Your Comment

Previous News

Next News

{{comment.Name}} made a post.
{{comment.DateTimeStampDisplay}}

{{comment.Comments}}

COMMENTS

0

There are no comments to display. Be the first one to comment!

*

Name Required.

*

Email Id Required.

Email Id Not Valid.

*

Mobile Required.

Email ID and Mobile Number are kept private and will not be shown publicly.
*

Message Required.

Click to Change image  Refresh Captcha
Unused tiffin, lunch box moulds

Unused tiffin, lunch box moulds

news-plastics-information